Your browser is unsupported

We recommend using the latest version of IE11, Edge, Chrome, Firefox or Safari.

Apr 7 2021

4/7 – Cynthia A. Chestek, University of Michigan

Special IEEE Distinguished Lecturer

April 7, 2021

5:00 PM - 6:30 PM

Address

Chicago, IL

Sponsored by the University of Illinois at Chicago IEEE-EMB Student Chapter

Title: Neural Interfaces for Controlling Finger Movements

Abstract:

Brain machine interfaces or neural prosthetics have the potential to restore movement to people with paralysis or amputation, bridging gaps in the nervous system with an artificial device. Microelectrode arrays can record from hundreds of individual neurons in the motor cortex, and machine learning can be used to generate useful control signals from this neural activity.
Performance can already surpass the current state of the art in assistive technology in terms of controlling the endpoint of computer cursors or prosthetic hands. The natural next step in this progression is to control more complex movements at the level of individual fingers. Our lab has approached this problem in three different ways.
For people with upper limb amputation, we acquire signals from individual peripheral nerve branches using small muscle grafts to amplify the signal. After a successful study in animals, human study participants have recently been able to control individual fingers online using indwelling EMG electrodes within these grafts.

For spinal cord injury, where no peripheral signals are available, we implant Utah arrays into finger areas of the motor cortex, and have successfully decoded flexion and extension in multiple fingers. Decoding “spiking band” activity at much lower sampling rates, we recently showed that power consumption of an implantable device could be reduced by an order of magnitude compared to existing broadband approaches, and fit within the specification of existing systems for upper limb functional electrical stimulation.

Finally, finger control is ultimately limited by the number of independent electrodes that can be placed within the cortex or the nerves, and this is in turn limited by the extent of glial scarring surrounding an electrode. Therefore, we developed an electrode array based on 8 um carbon fibers, no bigger than the neurons themselves to enable chronic recording of single units with minimal scarring. The long- term goal of this work is to make neural interfaces for the restoration of hand movement a clinical reality for everyone who has lost the use of their hands.

Contact

UIC Bioengineering

Date posted

Apr 1, 2021

Date updated

May 10, 2021